Zero Liquid Discharge (ZLD) Solutions
Water is
nature's most wonderful, most abundant, and most useful substance. It is
estimated that
Two-thirds of
earth's surface constitutes water. It also occupies a unique position in
industries. It
Plays a very important
role as a coolant for steam condensation in thermal power generation; it is
Also used as
a coolant in process plants. Water is very complex in nature and it contains a
lot of
Impurities in
dissolved and suspended form. Calcium and Magnesium salts present in water
Determine the
hardness of water and it is this hardness of water, which is the main cause for
HARD WATER
SCALE formation in heat exchangers in various industries.
OPTIMIZE
SPECIFIC STEAM CONSUMPTION, MINIMIZE WATER REQUIREMENT IN POWER PLANT
As you are
aware that vacuum in condenser of power plant plays a vital role in energy
consumption i.e.
As vacuum in
condenser is directly related to scale deposition, hence, if condenser tubes
remain scale free, the vacuum in condenser shall remain high i.e. around 0.1
ate and constant value in this connection, we wish to introduce a proven
technology of SCALE-BAN™ equipment which will give you the following savings
which is just impossible with any other technology for cooling water treatment:
Zero scale in condensers and other
coolers.
Constant vacuum of 0.1 ate in
condenser giving maximum efficiency.
in addition to above, there is
reduction of more than 25% - 30% water consumption in cooling tower.
SCALE-BAN™
Equipment is online non chemical water treatment equipment which is fitted just
before condenser and coolers in inlet cooling water line.
We have installed SCALE-BAN™ equipment at
various power plants ranging from 2.75 MW to 490 MW. All the Equipment have been performing
very well on the aspects of water conservation with zero scaling.
The savings
achievable by installing SCALE-BAN™ are as under:-
1. RO REJECT, ETP TREATED, RIVER &
BORE WELL water can be used as make up water in cooling tower to achieve
substantial saving in water while reducing the load to effluent treatment
plant.
2. As our equipment is tested to run
at very high hardness and TDS in cooling tower without any risk of scale
deposition, cooling tower can run at high COC of 15 TO 20 as against 3 to 5
with conventional treatment, so blow down from cooling tower becomes
negligible.
3. Water consumption in cooling tower
is reduced by more than 25%-30% and fresh water consumption can be brought down
to negligible (As RO reject & ETP treated water can be used as make up water).
4. Elimination of use of Softener
& anti-scaling chemicals from cooling tower.
5. There is GUARANTEED ZERO SCALE in
condenser and other coolers.
6. Vacuum in condenser in power plant
remains constantly on higher side (0.1 ate) which gives good efficiency of
plant and maintained specific steam consumption (SSC) [less coal consumption].
7. No Shutdown of plant is required
for cleaning of condenser tubes in power plant.
8. Due to repeated cleaning of the
hard scales in tubes with rod, the tube surface becomes weak and prone to leak.
Any leakage in condenser/cooler causes shutdown of minimum three days.
9. Ours is a fit and forget equipment
having a guaranteed maintenance free life of 20 years consuming no power.
Power Plant:-
No softening of water required.
Excellent Water Savings due to
reduced Blow Down with high COC.
Constant vacuum.
Chemicals Savings.
Distillery:-
Use of RO reject/ ETP treated
spent lease water as make up in cooling tower increased recovery of Alcohol.
Solvents
extraction:-
Increase in Hexane recovery.
Use of RO reject / ETP treated /
spent lease water as make up in cooling tower.
Dairy / Cold
Storage / A.C. Plants:-
constant cooling of ammonia / Freon gases.
Reduced power construction of
compressors due to constant pressure.
Other
Savings:-
No Softening Plants is required
hence recurring expenses for softening saved.
De-scaling chemicals are not
required cooling water.
as our equipment is tested to run
at high hardness (10000 ppm) and TDS (40000 ppm) in cooling tower without any
risk of scale deposition, cooling water can be run at high COC of 25 to 30 as
against 5 to 7 with conventional chemical treatments, so blow down from cooling
tower is negligible.
No shutdown of plant is required
for cleaning of Heat Exchanger / Condensers because of Zero scaling.
Due to repeated cleaning of the
hard scales in tubes with rod, the tube surface becomes weak and prone to
leakage, which is avoided due to Zero Scale.
SCALE-BAN™ is fit and forget
equipment having a guaranteed maintenance free life of 20 years consuming no
power.
ETP load significantly reduced.
No comments:
Post a Comment